#22
New
Bug
Other
7 Nov 2026
COM7 for TS-590SG not working
Here is the text from the terminal.
cmd:
*** PC drives the radio: couldn't open COM7 (Access to the path 'COM7' is denied.) - is another program (or HFConverse's own Terminal) using it? (Settings ▸ CAT Configuration ▸ Test Connection). ***
Martin MW0GBQ · developer · 7 Nov 2026
Hello,
Thank you for the report and the log. Your settings look right: the
modem opened on COM8, and HFConverse is set to control the TS-590SG
on COM7 at 19200 baud.
"Access to the path 'COM7' is denied" is Windows saying that another
program already has COM7 open - only one program at a time can use a
COM port. HFConverse itself only had COM8.
Please check for anything else that talks to the radio and close it
before connecting HFConverse, for example:
- Kenwood ARCP-590G
- a logging program with CAT (Log4OM, N1MM, HRD...)
- WSJT-X / JTDX / FLDigi
- OmniRig
- a second copy of HFConverse still running (check Task Manager)
Then connect HFConverse again, or press Settings > CAT Configuration
> Test Connection. If nothing else seems to be running, a restart of
Windows clears a port left open by a program that closed badly.
One more thing to check: the TS-590SG's USB gives two COM ports
("Enhanced" and "Standard" in Device Manager). CAT normally uses the
Enhanced one, at the baud rate set in the radio's menu (USB baud
rate). If COM7 is the Standard port, choose the other one.
73, Martin MW0GBQ
Martin MW0GBQ · developer · 8 Nov 2026
Hi Dave,
Thanks for checking. "Access denied" is Windows saying something
already has COM7 open, so let's find out what - it may be something
that starts with Windows without you noticing.
1. Without connecting HFConverse to the modem, open Settings > CAT
Configuration and press Test Connection. If it still says COM7 is
denied, it's definitely another program.
2. In Device Manager > Ports (COM & LPT), check COM7 is the TS-590SG's
"Silicon Labs Dual CP2105 ... Enhanced COM Port". If COM7 is the
Standard port, choose the Enhanced one in HFConverse.
3. To see which program holds the port, Microsoft's free Process
Explorer (search "Sysinternals Process Explorer") can tell you:
run it as administrator, then Find > Find Handle or DLL, and search
for Silabser - the result names the program that has it.
Programs that often grab COM ports quietly: logging or rig-control
programs in the system tray, OmniRig, virtual COM port tools, and
3D-printer, Arduino or GPS software.
Let me know what you find - and if Test Connection works when
HFConverse isn't connected to the modem, please send me a new log.
73, Martin MW0GBQ
#20
New
Bug
PACTOR
7 Nov 2026
IC-7300, HFC Not Read Freq. From Radio
The only anomoly I have noticed, at this time, is that HFC will execute a Set Frequency with the IC-7300. But, will not Read Frequency from IC-7300.
Martin MW0GBQ · developer · 7 Nov 2026
Hello,
Thank you for the report and the log - it shows exactly what's
happening.
Your settings are right: the modem accepts TRX TYpe ICOM 19200 $94,
and Set Frequency works (the radio moves). But when HFConverse asks
the P4 Dragon for the frequency, the Dragon returns an empty reply -
it doesn't pass the IC-7300's answer back in the mode HFConverse uses.
Other Dragon + IC-7300 owners see the same, so it's not your station.
Two ways round it:
1. Keep "Modem drives the radio" and tick "The radio can't report its
frequency (set it only)" in Settings > CAT Configuration. HFConverse
then sets the frequency as now, but stops trying to read it, so the
error messages go away.
2. Or let HFConverse control the IC-7300 directly over the radio's USB
port: Settings > CAT Configuration > "PC drives the radio", Make
Icom, Model IC-7300, the radio's USB COM port, CI-V Baud Rate as set
in the radio (or Auto), CI-V Address 94. Then the frequency is read
back too, and the Dragon just does PACTOR. The IC-7300 is confirmed
working this way.
I'm also looking into another way of reading the frequency through
the Dragon, which may remove the limit later.
73, Martin MW0GBQ
#19
New
Bug
PACTOR
5 Nov 2026
No ON/OFF, direct CQ
Hi, Martin,
This is an example of when I didn’t switch the monitor on and off but called CQ. Apparently, it works fine!
Initial state upon power-up: it looks as if the DR-7400 isn’t receiving anything. When I toggle the monitor on and then off, the LED indicators light up again.
I think this is such a minor issue that it’s not worth worrying about.
But I appreciate the explanation of "You're on the air". It’s clear to me now.
Have a nice evening,
73, Andrej
Martin MW0GBQ · developer · 5 Nov 2026
Hi Andrej,
Thanks - that explains it. The log shows the DR-7400 works normally after power-up even when the LEDs are dark: it was reporting signals on the frequency (busy channel) and your CQ went out fine. So it's only the front-panel LEDs that don't come on until the Monitor has been switched on and off - modem behaviour, not something going wrong in HFC.
If you have a moment after the next power-up, could you type "PMON STop" in the cmd: box (without switching the Monitor on first) and tell me if the LEDs come on? If they do, I can have HFC send that automatically when it connects to a Dragon, so you won't need the on/off any more.
Glad the "You're on the air" window makes sense now - I'll still make its wording clearer.
Have a nice evening,
73, Martin MW0GBQ
#17
New
Bug
Terminal
5 Nov 2026
Report: Monitor on ==> Monitor off
Report: Monitor on ==> Monitor off
Martin MW0GBQ · developer · 5 Nov 2026
Hi Andrej,
Thanks for the log (#17). HFC set up your DR-7400 exactly as on a good start, and the modem accepted everything. Your Monitor on / Monitor off came 22 seconds later, and before that the log shows the modem quietly in standby - so I still can't see what was wrong.
One thing is different from your good start: this time the modem had just been switched on (or reset) before HFC connected. Your earlier good start was with the modem already running from the last session. That may be the pattern.
Could you tell me:
1. What exactly do you see (or what doesn't work) when it's in the wrong state? For example: nothing shown when stations are on the frequency, no reply to a call, the status lamp, the radio...
2. Had you switched the DR-7400 off (or just powered it on) before those bad starts?
If you can, next time leave it in the wrong state for a minute and try what you normally do (listen, call or CQ), before pressing Monitor on/off - then send the log. That way it shows what fails.
73, Martin MW0GBQ
#16
New
Bug
PACTOR
5 Nov 2026
No CWI after UNPROTO - CWI set to CWI 3 4
Hi Martin,
could this be a SCS Firmware issue?
I love CW. I use CW. After unproto transmission, I like to send my CWI.
I use the END QSO (QRT) buttom to stop transmisson.
Is this right?
Is all queued text send when I use the END QSO (QRT) buttom?
Why does the P4 not tell the TRX to key up and why is the P4 not modulating the CW signal?
73 de sTef DM5TU
Martin MW0GBQ · developer · 5 Nov 2026
Hi Stef,
Thanks for report #16 and the log - it helped a lot.
End QSO (QRT): yes, that's the right button. In Unproto it sends D (a normal Disconnect), so anything still queued is sent first, then the modem ends the transmission. Stop TX (DD) is different: it stops at once, throws away anything not yet sent, and gives no CW ID. A few of your stops in the log were DD.
CWI setting: on the Dragon, "CWI 4" is PACTOR ARQ only - it never gives an ID after Unproto. You need 3, or 5 (= 3 plus an ID when the other station ends the link). Please change your command in Settings > Equipment > Own modem commands after connect from "CWI 4" to "CWI 5" (or "CWI 5 4" for the 6-second delay).
But: in your log you also tried "cwi 3" and "cwi 3 4", ended with D, and the Dragon still sent no ID. When it sends one, it prints "*** TRANSMITTING CW-IDENTIFICATION", and that line never appears - it goes straight to STBY. HFC sent the right command, so this looks like a firmware question for SCS. Could you try once more with the Monitor switched off (CWI 5, Unproto on, a line of text, then End QSO)? If there's still no ID, please ask SCS - I'm happy to help with the wording.
Why the radio isn't keyed in CW: on the Dragon the CW ID is always "audio only". The radio stays in USB with PTT held, and the ID is sent as the Mark tone switched on and off at 20 WPM (3 dB below your FSK level). So the radio doesn't change to CW - you hear the ID as a tone on your normal PACTOR frequency.
73, Martin MW0GBQ
#15
New
Bug
PACTOR
5 Nov 2026
MARCO F3 - Unproto TX sends CALLSIGN in WORKING box, after END QSO (QRT)
Hi Martin,
I use the UNPROTO e.g. to promote HFC on shortwave.
For my text sending in mode unproto I love to use my marcos.
At the end of my transmission I send my F3 macro "73" .
HFC does not recognize that this F3 marcos should not use the CALLSIGN in the WORKING box (in K2K window).
It sends out:
[THE CALLSIGN] which is typed in the Working box DE [MYCALL] etc.
Doesn´t make sense.
#SIDEQUESTION: When I use the Report a problem window, I cannot jump bach to the main program, for e.g. to search and copy text in the main windows.
Did you knew that?
Martin MW0GBQ · developer · 5 Nov 2026
Hi Stef,
Thanks for report #15 and the log - it shows exactly what you describe.
The F3 "73" macro: End QSO (QRT) leaves the Working box filled on purpose, so the QSO can still be logged. The next macro then picks up that old callsign, even in Unproto. As Unproto is also used for real QSOs with one station, I can't simply drop the callsign whenever Unproto is on. The plan is:
- an X button beside the Working box to clear it with one click
- while Unproto is on and the box is empty, it shows "ALL" in grey, and your macros send "ALL" where the callsign would go (for example "ALL DE DM5TU ... 73")
- outside Unproto nothing changes
Your side question: yes, Report a problem currently locks the main window until you close it. I'll change it to a normal window, so you can search and copy in the main window while it's open.
I also spotted something in your screenshot: the empty "cmd:" lines in the Received pane after switching Unproto off. Those are modem prompts that shouldn't show there - I'll move them to the Terminal log.
All three are on my list for the next version due out tomorrow
73, Martin MW0GBQ
#14
New
Bug
Terminal
5 Nov 2026
HFC at startup (DR-7400)
Hi Martin,
I am sending the report.
73, Andrej
Martin MW0GBQ · developer · 5 Nov 2026
Hi Andrej,
Thanks for the log. It shows a normal start: HFC set up your DR-7400 and the IC-7300 and everything was accepted. The modem then sat in standby and heard a few signals. It doesn't show the odd state, so I can't see the cause from it yet.
Next time it happens, please:
1. Note the time.
2. Leave HFC running and press Monitor on, then Monitor off, as you normally do to fix it.
3. Then save the diagnostic log and send it to me, with a word on what looked wrong before you pressed Monitor on/off.
That way the log covers both the bad state and the moment it comes right.
About the "You're on the air" window: it belongs to On the Air, not to the Monitor. When you switch the Monitor off while On the Air shows you as "Listening", HFC asks whether to keep showing you on the list. "Stay on the air" keeps your entry on the On the Air list; it doesn't switch the Monitor back on. I agree the wording is confusing, and I'll make it clearer.
73, Martin MW0GBQ
#13
New
Bug
Other
5 Nov 2026
TS-590SG COM Port connection setup doesn't work.
I can't connect my TS-590SG to HFConverse using the COM port setup.
I had to install and run this script to get hamlib connection working:
@echo off
start "" "C:\Program Files\hamlib-w64-4.7.2\bin\rigctld.exe" -m 2037 -r COM7 -s 19200 -T 127.0.0.1 -t 4532
exit
Martin MW0GBQ · developer · 5 Nov 2026
Hi, sorry to hear you are having connection issues. if you send me the diagnostic log it will tell me what's going on.
Set the rig up using the COM port again and try it when it doesn't work -> from HFC menu - Help- Report a problem it will by default attach the log file.
73
Martin MW0GBQ
#11
New
Bug
PACTOR
3 Nov 2026
Highlighting text issue - jumping cursor during Copy nd Paste process in K2K
Hi Martin.
When working with incoming text in the receice K2K window, the courser is set the first time on the target section, the window scrolls all the way up to the begining of that received window.
I can not pick the spot I wish to copy.
###SIDE WISH:
Please enable the .gif filetype for upload issues, here in Report a problem.
Martin MW0GBQ · developer · 3 Nov 2026
Hi Stef,
Thanks - I can see what's happening. The first click into the Received pane gives it the keyboard focus, and the pane then scrolls to the top of the text instead of staying where you clicked. The next version stops that, and it also holds the pane still while you have text selected, so incoming text doesn't pull it to the bottom while you're copying. Once you clear the selection it follows the new text again.
And your side wish is already done: Report a problem takes .gif files (animated ones too) in the next version.
73, Martin MW0GBQ
#10
New
Bug
PACTOR
3 Nov 2026
Direct control of IC-7300 after previously using HamlLib
Hi Martin
The program reports that it cannot control the radio, while in fact it does. So I do not know if it somehow ignores the direct setting and uses HamLib. Anyway, log attached, etc.
I will stick with HamLib for the moment.
73 Dave G4AON
Martin MW0GBQ · developer · 3 Nov 2026
Hi Dave,
Thanks for the log - it shows direct control working perfectly: HFC opened the IC-7300 on COM5, set USB-Data and the frequency, and read it back every few seconds for the whole session. No Hamlib involved.
I think the "can't control the radio" message came from Settings > CAT Configuration > Test Connection (or Test PTT). Could you confirm? While HFC is connected it already has COM5 open, so the test tried to open the port a second time and Windows refused - a false alarm. The next version will test through HFC's own open connection instead.
So you're fine to use direct control as it is - just ignore that test while connected. Hamlib is of course fine too.
73, Martin MW0GBQ
#9
Fixed
Bug
Other
Fixed in 0.1.0.6 · 2 Nov 2026
ICOM Cat
I use an ICOM radio, and controlling my IC-7300 via CAT (COM4, 19200, Hex94) works perfectly with all the programs I have used so far; unfortunately, it does not work with HFConvers, which is a real shame.
Please implement CAT control for the IC-7300 and other ICOM radios via a USB cable. Thank you.
Martin MW0GBQ · developer · 2 Nov 2026
This is now implemented in version 0.1.0.6 - marked as (Test), please try them and let me know how it goes.
73
Martin MW0GBQ
#8
New
Bug
Other
1 Nov 2026
Report-a-problem window too huge
- the lower buttons are not rechable
- the window cannot resized
#7
Fixed
Bug
PACTOR
Fixed in 0.1.0.5 · 1 Nov 2026
Prefix/ still not allowed in On The Air
The prefix you activated for V .4 still does not allow you to have a prefix/ and use On The Air
All the best,
Harley
Martin MW0GBQ · developer · 1 Nov 2026
Hi Harley,
Thanks for the log, it shows exactly what's happening. The 0.1.0.4 fix only covered the callsign HFConverse gives the modem: it now sends KN7H there, because PACTOR modems refuse the "/". On the Air still sends your full LA/KN7H to the On the Air server, and the server doesn't accept the "/", so your announcement is turned down. HFConverse should then have told you why, but the message was being replaced by "You're off the air". That's a second bug, and I'm fixing both.
You don't need to do anything. Once the server accepts a "/" in the callsign, On the Air will work with LA/KN7H as it is, and I'll let you know when it does.
73, Martin MW0GBQ
#6
Fixed
Bug
PACTOR
Fixed in 0.1.0.5 · 31 Oct 2026
Hej Martin,
Hej Martin,
in the new "Report a problem" window, I miss a bit the TITLE input field?
#ISSUE:
Ater copying a QRG out of the text field from DH1ME message, with internal copy. Than paste the QRG (3586,5) in Field CF kHz, the SET FREQUENCY feature is greyed out.
No further use of copied information. No QSY option.
#NEW FEATURE REQUEST:
Plesae think about a search funktion, in PACTOR received text.
Martin MW0GBQ · developer · 31 Oct 2026
Hej Stefan,
Thank you - a good catch. The frequency box only understood a decimal
point (3586.5), not the German decimal comma (3586,5), so Set Frequency
stayed grey. Worse, in the Terminal the comma was taken as a thousands
separator. That's fixed for the next version: "3586,5" and "3586.5"
both work everywhere. Until then, please type a point instead of the
comma.
The title field in Report a problem and a search in the received text
are both good ideas - I'm looking at them.
73, Martin MW0GBQ
#5
Fixed
Bug
PACTOR
31 Oct 2026
Hi Martin,
Hi Martin,
LA/KN7H could not be called.
HFC brought an invalied value Error.
The connect did not start at all.
73
Martin MW0GBQ · developer · 31 Oct 2026
Hi Stefan,
Thank you for the report and the log - it shows the cause clearly.
The P4 Dragon won't accept a "/" in a PACTOR connect: "C LA/KN7H" was
refused with "Invalid value", so nothing was sent. Your "C KN7H" a few
seconds later worked, because Harley's modem answers to KN7H.
Until it's fixed, put just the base callsign in Working (KN7H). Your
log and macros can still show LA/KN7H if you edit the QSO afterwards.
In the next version HFConverse will do this for you: with a "/" in
Working it calls the base callsign, says so in the Terminal, and keeps
LA/KN7H for the log and macros.
73, Martin MW0GBQ
#4
New
Bug
Terminal
30 Oct 2026
Hello Martin,
Hello Martin,
First of all, please accept my sincere thanks for your efforts on HFConverse.
I’ve been working on one problem all evening. Communication is working, as is frequency selection, but I’m having an issue in the Settings/Configuration/CAT Configuration window. I can’t run the Test Connection or Test PTT. It’s reporting an issue with COM4. As a result, “Read From Radio” probably isn’t working either. However, transmitting and changing frequencies do work. This suggests that COM4 is selected correctly. Where should I look for the cause?
Thanks in advance for your reply.
73, Andrej, S51SG
Martin MW0GBQ · developer · 31 Oct 2026
Hello Andrej,
Thank you for the kind words, and for the very clear report with
screenshots - it made this one easy to find.
It's a bug in HFConverse, not in your setup. With "Modem drives the
radio", Test Connection and Test PTT try to open COM4 a second time,
but HFConverse is already connected to the modem on COM4, and Windows
only allows one connection to a port. That is the "Access to the path
'COM4' is denied" message. It will be fixed in the next update: the
tests will then use the connection that is already open.
Your settings are correct: your modem shows Type ICOM, 19200 baud,
address 94, which matches Settings, and setting the frequency works,
so the cable and the CI-V address are fine.
Until the update:
- Read From Radio (in the Terminal or on the PACTOR screen) uses the
open connection, so it should work. Could you try it and let me know?
If it shows your radio's frequency, everything is working.
- If you want to run Test Connection now, use File > Disconnect from
modem first, then open Settings > CAT Configuration > Test Connection.
- Test PTT isn't needed: if your radio transmits when you send, the PTT
line is working.
73, Martin MW0GBQ